{"id":923,"date":"2025-05-26T12:25:23","date_gmt":"2025-05-26T10:25:23","guid":{"rendered":"https:\/\/www.heck-kaeltetechnik.de\/?post_type=technology&#038;p=923"},"modified":"2025-08-07T17:32:44","modified_gmt":"2025-08-07T15:32:44","slug":"direct-evaporation-systems","status":"publish","type":"technology","link":"https:\/\/www.heck-kaeltetechnik.de\/en\/technologies\/direct-evaporation-systems\/","title":{"rendered":"Direct evaporation systems"},"content":{"rendered":"\n<div class=\"wp-block-heck-header wp-block\"><div class=\"bild\"><div class=\"bild__image\"><\/div><\/div><div class=\"text\"><h1><span class=\"eyebrow\">Technologies &amp; solutions<\/span><span class=\"headline\">Experience is still the best expertise.<\/span><\/h1><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-bild-text wp-block reverse\"><div class=\"bild cropimage\"><div class=\"bild__image cropimage\"><img data-opt-id=1305942249  fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/StartbildDirektverdampfung.jpg\" alt=\"\"\/><\/div><\/div><div class=\"text\"><p class=\"eyebrow\">Direct evaporation systems<\/p><h2 class=\"headline\">Cost-saving direct evaporation systems\u00a0\u2013 efficient air cooling<\/h2>\n<p>In all applications in which large fresh or recirculating air flows are cooled, we offer you the&nbsp;advantages of direct&nbsp;evaporation technology.<\/p>\n\n\n\n<p>This involves direct cooling of the air through the evaporating refrigerant in the cooling coil&nbsp;\u2013 an&nbsp;intermediate medium such as&nbsp;chilled water is not required. You benefit from significantly better&nbsp;energy efficiency&nbsp;compared to&nbsp;conventional cooling systems. Additionally,&nbsp;the investment costs for&nbsp;complex&nbsp;cold-water piping including pumps and control&nbsp;groups are eliminated.<\/p>\n\n\n\n<p>.<\/p>\n<\/div><\/div>\n\n\n\n<section class=\"wp-block-group is-style-offset has-heck-hellgrau-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-heck-headline has-text-align-left\"><p class=\"eyebrow\">Features<\/p>\n<h2 class=\"wp-block-heading\">What our solutions have in common:<br>flexibility, efficiency and sustainability<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-heck-features wp-block\">\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=615035002  fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/benchmark.svg\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">Up to 40% lower <br>energy consumption<\/h3><p class=\"text\">through direct air cooling without an intermediate medium<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=1652951348  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/design.svg\"  class=\"optimole-lazy-only \"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">Turnkey <br>refrigeration system\u00a0<\/h3><p class=\"text\">including cooling coil, piping and commissioning<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=603434977  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/wartung.svg\"  class=\"optimole-lazy-only \"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">Highest <br>control accuracy\u00a0<\/h3><p class=\"text\">by stepless power control\u00a0<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=1782922419  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/regelung.svg\"  class=\"optimole-lazy-only \"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">Optional <br>heat recovery<\/h3><p class=\"text\">of the available waste heat from cooling process\u00a0<\/p><\/div><\/div>\n<\/div>\n<\/section>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:35%\">\n<div class=\"wp-block-heck-headline has-text-align-left\"><p class=\"eyebrow\">Keyfacts<\/p>\n<h3 class=\"wp-block-heading\">We optimize customer benefits through&nbsp;<br>comprehensive measures:<\/h3>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Reduction of trade interfaces\u00a0<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>through&nbsp;turnkey&nbsp;supply of the complete&nbsp;cooling system&nbsp;\u2013including&nbsp;refrigeration machine,&nbsp;pipework, cooling coil and control technology<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Small footprint and flexible installation<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>due to compact design and variable layout&nbsp;\u2013 ideal for decentralized retrofitting&nbsp;on existing installations<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Complete elimination of cold water technology<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>i.e.&nbsp;cold water generation, piping including insulation, buffer tanks \/ switches, primary and&nbsp;secondary pumps, cold water control groups and coils and frost protection measures are not&nbsp;required<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Reduction of investment and maintenance costs<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>by setting up combined systems for connecting several cooling coils with independent power&nbsp;control to one system<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Individual plant configuration<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>e.g. for indoor or outdoor installation,&nbsp;in&nbsp;compact or split design, air- or water-cooled, modular&nbsp;design, redundant \/ multi-circuit design, sound insulation<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Consideration of customer specifications<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>such as mechanical \/ electrical factory specifications, manufacturer specifications, special control&nbsp;cabinet equipment, communication interfaces, safety devices, etc.<\/p>\n<\/div><\/div><\/div><\/section>\n<\/div>\n<\/div>\n\n\n\n<section class=\"wp-block-group is-style-offset-sibling has-heck-grau-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-heck-headline has-text-align-left\"><p class=\"eyebrow\">Applications<\/p>\n<h2 class=\"wp-block-heading\">Areas of application of our direct evaporation systems include:<\/h2>\n<\/div>\n<\/section>\n\n\n\n<div class=\"wp-block-heck-anwendungen wp-block\">\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=403420107  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/lackierung.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Air conditioning of fully automated paint shops<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=555691478  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/lebensmittel3.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Production cooling in the food industry<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=637792467  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/pharmalager.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Warehouse cooling in the pharmaceutical industry<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=2081388549  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/elektronik.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Cooling of electronics manufacturing plants<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=1441335852  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/Einkaufszentrum.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Air conditioning of shopping\u00a0<br>centres<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=892263234  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/terminal.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Comfort air conditioning for terminals<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-heck-bild-text wp-block reverse\"><div class=\"bild false\"><div class=\"bild__image\"><\/div><\/div><div class=\"text\"><p class=\"eyebrow\">References direct evaporation systems<\/p><h2 class=\"headline\">Reliable and multifunctional technology\u00a0\u2013 successful in every application<\/h2>\n<p>Since 1979 we have been working with our global customers from a wide range of industries to&nbsp;find cost- and energy-saving&nbsp;solutions of the highest quality.<\/p>\n<\/div><\/div>\n\n\n    <section id=\"heck-references-block_1de2b9a1ea7d87f162c32894d0c3d449\" class=\"wp-block-heck-references\">\n        <div class=\"swiper-container\">\n            <div class=\"swiper-wrapper\">\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=662568485  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/Direktverdampfung_Heck1.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Air conditioning of a fully automated paint shop<\/span><\/h3>\n                                                                    <p>Pite\u0219ti, Romania<\/p>\n<ul>\n<li>7 direct evaporation systems<\/li>\n<li>Total cooling capacity of 1,140 kW<\/li>\n<li>Recirculating air + fresh air conditioning<\/li>\n<li>High energy savings through demand-based design<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=254597010  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/Direktverdampfung_Heck2.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Cooling of moisture-sensitive production processes<\/span><\/h3>\n                                                                    <p>Morsbach<\/p>\n<ul>\n<li>6 direct evaporation systems<\/li>\n<li>2,530 kW cooling capacity, 1,630 kW heating capacity<\/li>\n<li>Process air conditioning with heat recovery<\/li>\n<li>Elimination of complex cold-water piping for the customer<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1273812067  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/Direktverdampfung_Heck3.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Air cooling and dehumidification for food production<\/span><\/h3>\n                                                                    <p>Stadtallendorf<\/p>\n<ul>\n<li>4 split systems with heat recovery<\/li>\n<li>2,400 kW cooling capacity, 1,760 kW heating capacity<\/li>\n<li>Free of charge reheating with waste heat<\/li>\n<li>Retrofit thanks to flexible plant design with small footprint<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1447972310  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/Direktverdampfung_Heck4.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Process air conditioning in surface technology<\/span><\/h3>\n                                                                    <p>Mosonmagyar\u00f3v\u00e1r, Hungary<\/p>\n<ul>\n<li>DX system in split design<\/li>\n<li>220 kW cooling capacity, 190 kW heating capacity<\/li>\n<li>Highest control accuracy<\/li>\n<li>Dehumidification including reheating with waste heat<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1262048582  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/Direktverdampfung_Heck5.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Air conditioning of a large logistics centre<\/span><\/h3>\n                                                                    <p>Aldenhofen<\/p>\n<ul>\n<li>combined refrigeration system<\/li>\n<li>Total cooling capacity of 1,200 kW<\/li>\n<li>66 cooling coils with direct evaporation<\/li>\n<li>Split system for indoor installation with external condenser<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1124820595  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/Direktverdampfung_Heck6.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Air conditioning of an automotive paint shop<\/span><\/h3>\n                                                                    <p>Meppel, Netherlands<\/p>\n<ul>\n<li>15 water-cooled systems<\/li>\n<li>Total cooling capacity of 3,470 kW<\/li>\n<li>Compact design for decentralized installation<\/li>\n<li>Including recooling facilities and higher-level control system<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1599017241  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/Direktverdampfung_Heck7.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Fresh air cooling\/dehumidification for paint booths<\/span><\/h3>\n                                                                    <p>Gliwice, Poland<\/p>\n<ul>\n<li>Three-circuit refrigeration system (DX)<\/li>\n<li>1,740 kW cooling capacity<\/li>\n<li>Turnkey solution for the customer<\/li>\n<li>Maximum efficiency through direct air cooling without chilled water<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                            <\/div>\n        <\/div>\n        <div class=\"swiper-navigation\">\n            <div class=\"swiper-prev\"><\/div>\n            <div class=\"swiper-next\"><\/div>\n        <\/div>\n    <\/section>\n    ","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":924,"template":"","meta":{"_acf_changed":false},"class_list":["post-923","technology","type-technology","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/technologies\/923","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/technologies"}],"about":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/types\/technology"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/media\/924"}],"wp:attachment":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/media?parent=923"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}