{"id":946,"date":"2025-05-26T11:36:29","date_gmt":"2025-05-26T09:36:29","guid":{"rendered":"https:\/\/www.heck-kaeltetechnik.de\/?post_type=technology&#038;p=946"},"modified":"2025-08-08T15:47:50","modified_gmt":"2025-08-08T13:47:50","slug":"chiller-units","status":"publish","type":"technology","link":"https:\/\/www.heck-kaeltetechnik.de\/en\/technologies\/chiller-units\/","title":{"rendered":"Chiller units"},"content":{"rendered":"\n<div class=\"wp-block-heck-header wp-block\"><div class=\"bild\"><div class=\"bild__image\"><\/div><\/div><div class=\"text\"><h1><span class=\"eyebrow\">Technologies &amp; solutions<\/span><span class=\"headline\">Experience is still the best expertise.<\/span><\/h1><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-bild-text wp-block reverse is-style-default\"><div class=\"bild cropimage\"><div class=\"bild__image cropimage\"><img data-opt-id=832518694  fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/heck_kaltwassersaetze.jpg\" alt=\"\"\/><\/div><\/div><div class=\"text\"><p class=\"eyebrow\">Chiller units<\/p><h2 class=\"headline\">Individual chiller units\u00a0\u2013<br>tailored to your requirements<\/h2>\n<p>Our customized chillers for cooling of water or glycol\/brine as indirect&nbsp;cooling medium are&nbsp;used for&nbsp;a wide variety of process cooling and air conditioning applications and in all performance ranges.<\/p>\n\n\n\n<p>We develop your&nbsp;individual chilled water solution according to your specific requirements&nbsp;\u2013 e.g.&nbsp;regarding dimensions, noise emissions, control accuracy,&nbsp;supply temperatures, ambient conditions,&nbsp;operational safety or factory&nbsp;specifications.<\/p>\n<\/div><\/div>\n\n\n\n<section class=\"wp-block-group is-style-offset has-heck-hellgrau-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-heck-headline has-text-align-left\"><p class=\"eyebrow\">Features<\/p>\n<h2 class=\"wp-block-heading\">What our solutions have in common:<br>flexibility, efficiency and sustainability<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-heck-features wp-block\">\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=615035002  fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/benchmark.svg\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">Maximum<br>energy\u00a0efficiency<\/h3><p class=\"text\">through intelligent control and drive concepts<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=1652951348  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/design.svg\"  class=\"optimole-lazy-only \"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">Flexible<br>plant design<\/h3><p class=\"text\">by project-specific\u00a0<br>engineering<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=603434977  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/wartung.svg\"  class=\"optimole-lazy-only \"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">High ease of<br>maintenance \/ service<\/h3><p class=\"text\">including optional remote monitoring<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-feature wp-block\"><div class=\"bild undefined\"><img data-opt-id=1782922419  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/ig:avif\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/regelung.svg\"  class=\"optimole-lazy-only \"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><h3 class=\"headline\">Individual<br>control concept<\/h3><p class=\"text\">for ideal integration into the overall process<\/p><\/div><\/div>\n<\/div>\n<\/section>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:35%\">\n<div class=\"wp-block-heck-headline has-text-align-left\"><p class=\"eyebrow\">Keyfacts<\/p>\n<h3 class=\"wp-block-heading is-style-h3\">We optimize customer benefits through comprehensive measures:<\/h3>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Realization of highest performance figures<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>through optimized component design and the use of frequency-controlled compressors and pumps,&nbsp;electronic expansion valves, EC fans, etc.<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Integral energy-saving concepts<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>through optional&nbsp;integration of&nbsp;free cooling for winter&nbsp;operation or heat recovery to&nbsp;use&nbsp;freely&nbsp;available waste heat<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Environment-friendly and future-proof refrigerants<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>with low GWP values&nbsp;(\u201clowGWP refrigerants\u201d)&nbsp;and low safety requirements, optionally including&nbsp;leakage&nbsp;monitoring system<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Individual plant configuration<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>e.g. for indoor or outdoor installation,&nbsp;in&nbsp;compact or split design, air- or water-cooled, modular&nbsp;design, redundant \/ multi-circuit design, sound insulation<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Integration of hydraulic\u00a0equipment<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>e.g. primary  \/secondary pumps, buffer tanks \/ hydraulic&nbsp;switches, control valves or heat exchanger&nbsp;modules<\/p>\n<\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-heck-accordion section wp-block\"><div class=\"wrapper\"><div class=\"accordion_head\"><span class=\"trigger\"><svg width=\"39\" height=\"38\" viewBox=\"0 0 39 38\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"19.5\" cy=\"20\" r=\"16\" fill=\"#EEEFF0\"><\/circle><path d=\"M17.5 12.7667L24.1667 19.4334L17.5 26.1\" stroke=\"#0C619E\" stroke-width=\"2\"><\/path><\/svg><\/span><div><h2 class=\"title\">Consideration of customer specifications<\/h2><\/div><\/div><div class=\"inner\"><div>\n<p>such as mechanical \/ electrical factory specifications, manufacturer specifications, special control&nbsp;cabinet equipment, communication interfaces, safety devices, etc.<\/p>\n<\/div><\/div><\/div><\/section>\n<\/div>\n<\/div>\n\n\n\n<section class=\"wp-block-group is-style-offset-sibling has-heck-grau-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-heck-headline has-text-align-left\"><p class=\"eyebrow\">Applications<\/p>\n<h2 class=\"wp-block-heading\">Areas of application of our chiller units include:<\/h2>\n<\/div>\n<\/section>\n\n\n\n<div class=\"wp-block-heck-anwendungen wp-block\">\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=710947043  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/kuehlung-it.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Cooling of IT data centers<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=1122879645  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/prozesskuehlung.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Process cooling in food production<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=1626838417  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/temperierung.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Temperature control of process baths in surface technology<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=2053693645  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/kuehlung-spritzguss.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Cooling of injection molding machines<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=1140970618  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/rueckkuehlung.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Re-cooling of ozone generation plants<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-heck-anwendung wp-block\"><div class=\"bild undefined\"><img data-opt-id=70515301  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/05\/kaltwasser.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\"\/><\/div><div class=\"text\"><p class=\"headline\">Cold water generation for comfort air conditioning<\/p><\/div><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-left\"><\/p>\n\n\n\n<div class=\"wp-block-heck-bild-text wp-block reverse\"><div class=\"bild false\"><div class=\"bild__image\"><\/div><\/div><div class=\"text\"><p class=\"eyebrow\">References chiller units<\/p><h2 class=\"headline\">Reliable and multifunctional technology\u00a0\u2013 successful in every application<\/h2>\n<p>Since 1979 we have been working with our global customers from a wide range of industries to&nbsp;find cost- and energy-saving&nbsp;solutions of the highest quality.<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"has-text-align-left\"><\/p>\n\n\n\n<p class=\"has-text-align-left\"><\/p>\n\n\n    <section id=\"heck-references-block_5a1e61f88a732a2d6aa33ea7bc49320d\" class=\"wp-block-heck-references\">\n        <div class=\"swiper-container\">\n            <div class=\"swiper-wrapper\">\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1806183539  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/kaltwassersaetze_Heck1.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>High-efficient cooling of process bath for car body painting<\/span><\/h3>\n                                                                    <p>Ludwigsfelde<\/p>\n<ul>\n<li>Chiller unit including free cooling<\/li>\n<li>500 kW \/ 200 kW free cooling<\/li>\n<li>Ultra-low noise exterior housing<\/li>\n<li>Highest efficiency for optimal seasonal performance<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=345065968  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/kaltwassersaetze_Heck2.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Production cooling with heat recovery<\/span><\/h3>\n                                                                    <p>Warendorf<\/p>\n<ul>\n<li>Chiller unit with heat recovery<\/li>\n<li>390 kW cooling \/ 500 kW heating<\/li>\n<li>High-efficiency design<\/li>\n<li>Refrigeration system with variable heat recovery and residual heat condenser<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1522578803  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/kaltwassersaetze_Heck3.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Chiller unit with low-GWP refrigerant<\/span><\/h3>\n                                                                    <p>L\u00fcdenscheid<\/p>\n<ul>\n<li>A2L chiller unit in split design<\/li>\n<li>620 kW cooling capacity<\/li>\n<li>2 fully redundant circuits<\/li>\n<li>In a weatherproof housing including frost protection and primary pumps<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1599350368  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/kaltwassersaetze_Heck4.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Peak-load cooling for process water in the furniture industry<\/span><\/h3>\n                                                                    <p>Kirchlengern<\/p>\n<ul>\n<li>3 separate chillers<\/li>\n<li>Total cooling capacity of 850 kW<\/li>\n<li>Split design<\/li>\n<li>External, air-cooled condensers in low-noise design<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=389435044  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/kaltwassersaetze_Heck5.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Customized refrigeration system for automotive supplier<\/span><\/h3>\n                                                                    <p>Feuchtwangen<\/p>\n<ul>\n<li>Chiller unit in compact design<\/li>\n<li>750 kW \/ 500 kW free cooling<\/li>\n<li>Redundant design<\/li>\n<li>For maximum availability, including hydraulic module + free cooling<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                                    <div class=\"technology swiper-slide reference\">\n                                                    <div class=\"reference__image\">\n                                                                    <img data-opt-id=1125889605  data-opt-src=\"https:\/\/mlmktbtygrww.i.optimole.com\/w:auto\/h:auto\/q:mauto\/f:best\/https:\/\/www.heck-kaeltetechnik.de\/wp-content\/uploads\/2025\/06\/kaltwassersaetze_Heck6.jpg\"  decoding=\"async\" src=\"data:image/svg+xml,%3Csvg%20viewBox%3D%220%200%20100%%20100%%22%20width%3D%22100%%22%20height%3D%22100%%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%3E%3Crect%20width%3D%22100%%22%20height%3D%22100%%22%20fill%3D%22transparent%22%2F%3E%3C%2Fsvg%3E\" alt=\"\">\n                                                            <\/div>\n                            <div class=\"reference__text\">\n                                <h3 class=\"technology__title\"><span>Simultaneous cooling and heating supply for production<\/span><\/h3>\n                                                                    <p>Kalkar<\/p>\n<ul>\n<li>Chiller unit in compact design<\/li>\n<li>490 kW cooling \/ 720 kW heating<\/li>\n<li>100% waste heat utilization<\/li>\n<li>Designed for maximum efficiency<\/li>\n<\/ul>\n                                                            <\/div>\n                                            <\/div>\n                            <\/div>\n        <\/div>\n        <div class=\"swiper-navigation\">\n            <div class=\"swiper-prev\"><\/div>\n            <div class=\"swiper-next\"><\/div>\n        <\/div>\n    <\/section>\n    \n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":975,"template":"","meta":{"_acf_changed":false},"class_list":["post-946","technology","type-technology","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/technologies\/946","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/technologies"}],"about":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/types\/technology"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/media\/975"}],"wp:attachment":[{"href":"https:\/\/www.heck-kaeltetechnik.de\/en\/wp-json\/wp\/v2\/media?parent=946"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}